Go to Asahi Kasei Japan
Home > Library > QyuSpeed™ > Flow-Through Mode

Flow-Through Mode

Even when operating under a wide variety of conditions during biopharmaceutical manufacturing processes, QyuSpeed D demonstrates both a high target protein recovery rate and an excellent capacity for impurity removal.

 

Pre-Protein A Chromatography Use

Pre-protein A chromatography protein solutions were processed with QyuSpeed D. IgG recovery and HCP removal were measured in the filtrates.

Composition of Sample Protein Solutions
IgG: 1 mg/mL
HCP: 0.2 mg/mL
NaCl: 0.1 M
Buffer: 20 mM Tris-HCl (pH 7.5)

Post-Protein A Chromatography Use

Post-protein A chromatography protein solutions were processed with QyuSpeed D. IgG recovery and HCP removal were measured in the filtrates.

Composition of Sample Protein Solutions
IgG: 1 mg/mL
HCP: 0.1 mg/mL
NaCl: 0 M
Buffer: 20 mM Tris-HCl + 10 mM Citrate + 10mM Phosphate (pH 7.0)

Post-Cation Exchange Chromatography Use

Post-cation exchange chromatography protein solutions were processed with QyuSpeed D. IgG recovery and HCP removal were measured in the filtrates.

Composition of Sample Protein Solutions
IgG: 1 mg/mL
HCP: 0.1 mg/mL
NaCl: 0.15 M
Buffer: 20 mM Tris-HCl + 10 mM Acetate (pH 6.0)